E.Win Readme File ----------------- [29.06.2020] * 2.1.2.26 R2: - updated ekeylib.dll to support EL70P (USB) and EL70F (LAN). - Second fields (hhmmss) support for transaction record * For certain models of controllers only. - Popup configure EL70P (USB) if > 1 serial port is detected. - Option to disable '*' marking in name field for expired cards. - Fixed bug: door accessibility duplicated records - Allow customized access level handling: * tick selected controllers only. [01.11.2018] * 2.1.2.18 - F18 bug fixes - Bulk Command support added. Controllers: EL2305 / EL2306 / EL1375 - v 2.5.03 onward * Edit EdotWin.ini: [Options] BulkCmd=1 * Useful for to a single controller a. Double click on the controller icon of your choice b. Click | c. Click d. The progress bar will start moving after few seconds. e. Roughly 43 seconds for 1000 cards (multidrop - baud 2400) - Secure Command support added. Controllers: EL2305 / EL2306 / EL1375 - v 2.5.03 onward a. Edit EdotWin.ini: [Options] SecComm=1 b. Cold start the controller - Main Menu - press <#> --> Clr Sec c. Press to select YES, then <#> to clear code. * How to Reset WinPro for cold-started-clear-code controller: a. Run Designer b. Select Setup | Advanced Options c. Select controller, then click [17.12.2015] v 2.1.1.58 1. Manager - Fixed I/O status not refresh bug. - Blocked duplicate department/position entries. - Add NetDir setting to deal with errors caused by Paradox table sharing. 2. Chronos - Updated to 1.0.0.97 [12.08.2015] v 2.1.1.43 1. Manager - Fixed E.Win Excel export - not order by time. - Redirect Email to Web based Mail Server. - Fixed F18.EvenUnitAsExit=1 error. - Unlock E.Win to back to FREE 4 doors. [06.03.2015] 2.1.1.40 ======== 1. Manager - Add C7 support. - Fixed EL2201 controller type bug. - Add [ZKFP] FingerORCard=1 to turn on FingerORCard - Fixed Old-Card-Not-Removed bug - Fixed E.Win+F8 TimeZone error - Add ScanResumeSec=60 to allow auto-resume of polling. [Comm Setting] ScanResumeSec=60 [13 Sep 2013] 2.1.1.9 ======= 1. Manager - Fix dns:port bug in UseDomainName. - Allow >4 web simultaneous login. - Add EK3KS OutRdr support. - Add [EL3KS] UpdateMTZ=1 to update EL3KS master unit card TZ. - Add time range to ExportTrans screen. - Add SMS support in Conditional I/O - Done. [29 Jan 2013] 2.1.0.26 ======== 1. Manager - *.raw file genrated for F8/C3 controller. - *.raw does not contains IP Address - added. - EL3000S template management support added. - IMail.Exe added to handle Email authentication [Email] UseIMail=1 - EL3000S template management support added. [EL3KS] Enable=1 Master=CTRL001 - Add F18 (Color LCD) support. - Add F8 downtime retry wait: [ZKFP] RetryWaitSec=50 - Allow user defined delay (msec) in conditional emails: [Email] IMDelay=200 - Support F8/F18 on Algorithm 10.0: [ZKFP] Alg10=1 - Fixed El23xx/EL137x slow polling (2 sec delay) bug. - option added to Utilities menu. - Show user fields in Cards datagrid. - Access Report - allow viewing Second Card trans. - Block user from adding blank text entry. - Add [System] AlarmWavFile - sound card based Alarm siren. - Allow Direct photo Capture into Card database. - Remove old card if user changed card number in Card screen. - Add F8/C3 PLR on/Off - in case of Fire Alarm Integration. - CarPark button in Controller screen disabled - fixed. - CarPark Fullsign, LotSize & ResetCounter bugs - fixed. - Audit trails on Accessibility & Card Edits & Timer/TZ added. - AreaTrace: report viewing on One Area not filtered - fixed. - Fixed EL23xx not supporting LockReleaseTime bug. - Fixed AreaTrace report name/staff number overlapped bug.(if long staff name). - Add FR1200 support as F8/F18 Exit Reader. - Fixed "Send All cards to 1 controller" bug. - Card Import: now extra characters are cropped properly, single quote handled (e.g. Dato' --> Dato). - Added New icons for EL23xx and EL137x. - Able to recover from comm port failure. e.g EL70Y USB cable drop out. - Expiried cards notifications. - Traffic report for each controller. - Fixed 'DOWN' icon problem. - Export Card DB option added. - Add [System] g_sAlarmWavFile - use *.wav file for Alarm siren instead of beeping. - *.Raw file includes IP address to uniquely identify the records. - Added EL3000S template management support. - Audit trails on Accessibility & Card Edits & Timer/TZ added. - IMail.Exe to handle Email authentication [Email]UseIMail=1 - AreaTrace: report viewing on One Area not filtered - fixed. 2. Designer - Added new icons for EL23xx and EL137x. - F18 Support - Fixed bug in version detection. - Add echo test option in Version-Detect screen. - Meant for trouble-shooting serial communication. [20 Oct 2011] 2.0.9.26 ======== 1. In General - During installation, 'Templates' sub-folder is not created for ER301 - fixed. 2. Manager - Fixed ER301 phantom entries if controller is deleted. - Added setting to handle socket timeout: [Comm Setting] IPTimeOut50ms=200 - FC1200, added delay for card downloading. [Options] EL1x00CardDelayMsec=60 - Add FC1000 icon. - Fixed E.Win web.timer display error. - Fixed 'Deleted card not reflected in E.Time'. - Display version number on main screen. - Add OnStartSendDT to update controller date/time upon starting, if enabled. [Options] OnStartSendDTSec=1 3. Designer (2.0.6.10) - Low level settings / Conditional Email - display in Chinese - done. - Add FC1000 Icon. 4. Chronos - 1.0.0.84, updated from 1.0.0.66. - Add auto leave balance reset function when reaching cut-off date. - Leave balance before cut-off date will become carry forward day. - Add option to allow user to change the default total leave days allocated. - Fixed exempted cannot be saved on employee screen. - UBS payroll integration: Add option to post data for 1st half or 2nd half payroll - Add designation field in data format. - Fixed the attendance daily details and attendance details by employee report do not have line at last row problem. - Fixed recycle card problem when import raw data. - Display holiday settings as readonly. - Import clocking data: Block duplicate clocking data from being imported. - Prevent leave type to be deleted if the leave type still in used. - Display version number on the main screen status bar. [27 Apr 2011] 2.0.9.13 ======== 1. Manager - Fixed system user entry - corrupted by Chinese characters. - Add Email support - based on Conditional I/O screen. (Included in Web Module, thus require web module license) - Tidy up Starting/Expiry date enforcement routines. 2. Designer - Conditional I/O screen expanded to support E-mail. - Low Level Settings support added for new model of EL1335: * MasterCard / Sensor type / Warm start / etc. [23 Nov 2010] 2.0.9.10 ======== In general, this version has been optimized to allow smooth installation on 64-bit OS such as Windows 7, without worrying on the default 'c:\program files (x86)', and EL70Y driver. ET_Link has been updated to version 1.0.5 to take care of the default folder of 'c:\program files (x86)' if 64-bit OS is detected. 1. Manager - Add Status display when extracting transactions for view/print. - Add Status display when updating E.Time employee database. - Error transferring staff info to E.Time if data contain single quote - fixed. - Interfacer option added. - ER301 fingerprint reader support added. - Add 'Unidentified' and 'Unverified' transactions. - Supports multiple templates per staff, IN/OUT Reader per controller. - Expired cards not highlighted in database screen - fixed. - Allow Cards/Controller DB sorting by clicking on column title. - Close Chronos when exit. 2. Designer - Allow sorting by clicking on controller title bar. - Add 'Fit to screen' option if floor plan is too large for the screen resolution. [28 July 2010] 2.0.9.1 ======= 1. Designer - New ELID logo 2. Manager - New ELID logo - Double-click controller icon to view cards in that controller bug - fixed. [15 March 2010] 2.0.8.21 Beta ======== 1. Designer - Cond I/O chinese chinese characters display fixes. 2. Manager - Chinese characters display fixes. [17 September 2009] 2.0.7.43 ======== 1. Designer 1.1 Conditional I/O - deletion not working properly - fixed. 2. Manager 2.1 Audit Trail did not display as yyyy/mm/dd when set - fixed. 2.2 Optional fields now supported properly: Card import format: comma delimited. Max Length ---------- Operation 1 A or D Staff number 12 Card number 6 Name 50 department 25 job title 25 misc 20 (optional) PIN 4 digits (optional) Access level 12 (optional) Starting date 8 yyyymmdd (optional) Expiry date 8 yyyymmdd (optional) photo 30 (optional) NOTE: ----- if photo is to be imported, then those BMP/JPG files must be placed under the same folder as the card import text file. 3. Chronos 3.1 (1.0.0.46) fixed the FILO bug. (OT_INI not updated) 3.2 yyyy/mm/dd display - feature added. 3.3 Chinese help file (GB) added. 2.0.7.37 ======== 1. Designer 1.1 Chinese online help file support added. 1.2 Sensor/Output screen: blank controller tag - fixed. 1.3 Controllers on map B are accidentally removed when map A is deleted - fixed. 2. Manager 2.1 System user DBGrid title - not in chinese - fixed. 2.2 Label/Title not displayed properly in chinese - fixed. (Sensor Popup/DB/SysSetup/Priority Levels/Cards) 3. Chronos 3.1 Fixed chinese tag '?1' error for department/designation. 2.0.7.35 ======== 1. Fixed Chinese display error in Audit Trail, export trans, access report, error messages etc. 2. Allow date format to be set as yyyy/mm/dd. You can set it through Setup | Preferences | Options | yyyy/mm/dd. 3. Introduce: [Options] OTPCutOffTime=hhmm to allow proper processing of attendance, esp. those across midnight. 4. Provide more comprehensive export filter. 5. Chinese Online help / Manual added (Both GB & Big5 format). 2.0.7.32 ======== 1. "Output" table logical field error - fixed. E.Win did not read the right working schedule if user changed them in Choronos. - fixed. 2. Conditional I/O not working properly under Chinese GB mode - fixed. 3. (E.Key) License detection problem fixed. (For both Manager & Designer) 4. By default, Web server is off (to avoid conflict with IIS/Apache). So, to turn on Tiny Web Server, please stop running IIS/Apache. or, alternately, set the Tiny Web Server to listen on port other than 80. Now, you can enable Tiny Web Server in Preferences screen. 5. Added 'Upload and Transfer' option for those cards installed directly at controller using Master Card. This option allows the user to quickly add cards (say 200 cards) to E.Win using one of the doors, then upload to PC and imported to Card Database directly. 6. Changed latest Photo display to be enabled by default. Creating a new controller will automatically set the controller for photo display. Default transactions to trigger the photo display includes: Valid Entry/Exit, Invalid Entry, Wrong Pin, Wrong Time Zone and Duress Alarm. 2.0.7.30 ======== 1. From this version onwards, E.Win installation file will come with Chronos - meaning that once installed, you will have both E.Win & Chronos, properly configured. 2. Designer - Can set directly Comm/Bus in the Detect screen. - Auto turn on MultiCommSupport once controllers on other buses are defined. - Allow IP controller version check. - Bug fixed: when the last floor plan is deleted, button is accidentally disabled. 3. Manager - Now default to detect key, previous version has set LimitedEdition=1, causing confusion for those using License key. - Those who used to LimitedEdition can still turn on the mode by INI file or set it in Preference | Option screen. - online transaction monitor now restore the screen from previous session, instead of a blank screen upon start up. 4. On-the-fly Multi-language support - Now you can select language to be used from Preference | Option. - The Web pages replied from Built-in tiny web server will be in the selected language. For 2.0.7.28 or earlier version =============================== A. Integrate with Chronos (Default) ----------------------------------- By default, E.Win is pre-configured to integrate to Chronos. Steps ===== 1. Install E.Win, then Chronos. 2. Install Chr_Link. B. Integrate with E.Time ------------------------ Steps ===== 1. Install E.Win, then E.Time. 2. Install ET_Link. NOTE: ===== [1] E.Win+Chronos or E.Win+E.Time integrations has been pre-configured based on default folders. If you change the folder/drive, you need to edit the INI files accordingly. [2] E.Win is defaulted to Limited Edition (Maximum 4 controllers, without using EsofKey2), at COM1. If you use other comm port to link to the controllers, you can set it under: | If you have more than 4 controllers, please turn off the setting by editing the EdotWin.Ini file: [Options] LimitedEdition=0 [3] Please take note that EL2307 is preset at Baud 9600, so if E.Win failed to communicate to multi-drop linked EL2307, you may try to set E.Win to run at Baud 9600. Alternatively, you can set baud rate of EL2307 to 2400. * * * End of File * * *